z/OS Service Package: X2016032


SMP/E SYSMOD:
Component:
Operating System:
Publish Date:
APAR & Description:

RS33001
SELCOPYi
z/OS
2016/02/02

IQ004502:

The SELCOPYi DB2 audit log data set name prefix now defaults to be the installation default as defined for each user via INI option: SYSTEM.UserDSNPrefix.

Previous default was the user's ACF security manager logon id.

Furthermore, this prefix is no longer truncated at 8 characters, so allowing a prefix comprising a number of 8 byte qualifiers if needed.

Note that the default DB2 audit log DSN prefix may be overridden using the DB2 Audit File Settings panel (=0.7.1).



SMP/E SYSMOD:
Component:
Operating System:
Publish Date:
APAR & Description:

RS33002
SELCOPYi
z/OS
2016/02/02

IQ004438, IQ004505, IQ004506, IQ004565:

Miscellaneous fixes relating to SELCOPYi SDO structure creation:
  1. ZZSD263W warning messages suppressed when creating a permanent or temporary SDO structure from a COBOL copybook using the Enterprise COBOL 5.1 compiler.

    These were caused by new level 1 special register entries in the list output generated by this version of the COBOL compiler.

  2. Correct ZZSD100E and ZZSD264E errors which occurred when creating a structure from a COBOL copybook where a record-type name is a REDEFINES of another data element.

  3. Correct failure by SELCOPYi to create a structure from a COBOL copybook containing a field named FILLER that REDEFINES another field.

  4. Prevent creation of a structure with multiple record-types named FILLER.

    This occurred when the structure was created from a COBOL copybook where record-type definitions were based on 2nd (or higher) level group items named FILLER. For each group name FILLER, SELCOPYi now generates a record-type with a name in the format FILLnn (i.e. FILL01-FILL99).

    Additionally, SELCOPYi no longer defaults to automatic generation of multiple record-types if 2nd level data elements all REDEFINE each other. This behaviour is a non-default option (See Settings->Data Edit).

IQ004558:

Prevent abend at MEMFBSP0+0C38 when running an SDEAMAIN batch job with in-stream SDEIN (//SDEIN DD *) that occured only if the submitting user had no (OMVS) HFS Home directory defined.



SMP/E SYSMOD:
Component:
Operating System:
Publish Date:
APAR & Description:

RI33001
SELCOPY
z/OS
2016/02/02

SQ012202:

For SELCOPY DB2 log (CBLSQLOG) output, the DB2 version number in message CBLS000I now displays correctly for DB2 versions 10 and later.

Previously displayed as 9.9.9.